Powered by GoogleTranslate

Inspection Detail

Inspection: 126008549 - Sundance Natural Foods Co.

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 126008549
Report ID: 0950632
Date Opened: 03/08/1999

Site Address:
Sundance Natural Foods Co.
12227 Mesa Verde Rd
Valley Center, CA 92082

Mailing Address:
2231 Willow Brook Dr, Oceanside, CA 92056

Union Status: NonUnion

SIC:0723

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/14/1999

Emphasis:

Case Closed: 08/25/2008


Related Activity
Type Activity Nr Safety Health
Accident 361639669
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 5 9
Current Violations 2 6 8
Initial Penalty $10,000 $0 $0 $815 $0 $10,815
Current Penalty $4,135 $0 $0 $1,365 $0 $5,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 14301 A01 05/05/1999 06/07/1999 $275 $275 $0 -  
2. 01002 Other 2947 05/05/1999 06/07/1999 $135 $135 $0 -  
3. 01003 Other 3203 A 05/05/1999 06/07/1999 $135 $135 $0 -  
4. 01004 Other 3439 A 05/05/1999 06/07/1999 $135 $135 $0 -  
5. 01005 Other 3439 B 05/05/1999 06/07/1999 $135 $135 $0 -  
6. 02001 Serious 2946 A 05/05/1999 06/07/1999 $0 $4,000 $0 F - Formal Settlement Citation has been deleted.
7. 03001 Serious 2946 B03 05/05/1999 06/07/1999 $4,000 $4,000 $0 -  
8. 04001 Other 3441 A06 05/05/1999 06/07/1999 $550 $1,000 $0 F - Formal Settlement  
9. 05001 Serious 3457 C01 A 05/05/1999 06/07/1999 $135 $1,000 $0 F - Formal Settlement  

Investigation Summary

Investigation Nr: 126008549
Event: 03/08/1999
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

A farm worker was unloading produce packing crates. The employee was experienced in performing this job. He had parked his truck and was raising a 5.2-meter hydraulic boom mounted on the back of his 1997 Mitsubishi Fuso Truck (Model FM-SP). He was standing at the right rear of the truck, using a pendant control to guide the boom into position. (The boom was manufactured by Frank's Welding.) The boom contacted a 12-kilovolt overhead power line, and the employee was electrocuted.

Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, BOOM, AGRICULTURE, ELECTROCUTED, TRUCK BOOM, E AG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126008549 Fatality Electric Shock Farm workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close