Powered by GoogleTranslate

Inspection Detail

Inspection: 126005867 - Ogden Sigc Geothermal Inc

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 126005867
Report ID: 0950632
Date Opened: 11/13/1998

Site Address:
Ogden Sigc Geothermal Inc
855 Dogwood Rd
Heber, CA 92249

Mailing Address:
Po Box 1500, Heber, CA 92249

Union Status: NonUnion

SIC:3621

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/30/1999

Emphasis:

Case Closed: 08/13/1999


Related Activity
Type Activity Nr Safety Health
Accident 361637671
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 5 1 6
Initial Penalty $9,500 $0 $0 $375 $0 $9,875
Current Penalty $9,500 $0 $0 $375 $0 $9,875
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5189 F01 C 04/30/1999 06/02/1999 $375 $375 $0 -  
2. 02001 Serious 5189 K01 04/30/1999 05/12/1999 $4,500 $4,500 $0 -  
3. 03001 Serious 5189 H01 04/30/1999 05/12/1999 $1,250 $1,250 $0 -  
4. 04001 Serious 5189 F04 04/30/1999 06/02/1999 $1,250 $1,250 $0 -  
5. 05001 Serious 3382 B 04/30/1999 05/12/1999 $1,250 $1,250 $0 -  
6. 06001 Serious 5146 C 04/30/1999 05/12/1999 $1,250 $1,250 $0 -  

Investigation Summary

Investigation Nr: 201061843
Event: 11/03/1998
Employee Burned by Vapor

On November 3, 1998, Employee #1 was working as part of a three-worker crew conducting boroscope readings inside a tube heat exchanger at a geothermal energy plant. The boroscope utilized a high-temperature halogen light source and was plugged into a 120-volt extension cord. A second work crew removed a valve from a vessel containing isopentane vapor, approximately 8 feet away from the boroscope. In approximately 7 seconds, the vapor cloud released from the vessel was ignited by either the boroscope, extension cord, or other related equipment. Employee #1, who was reading the meter for the boroscope in a slightly sunken area of the ground surface, was caught in the vapor cloud and burned. Written procedures of the geothermal energy plant, which required a hot work permit for any electrically-operated equipment, were not followed. Also, none of the workers involved in the incident were wearing fire-protective clothing. Employee #1 was hospitalized, suffering from second- and third-degree burns on both of his arms.

Keywords: BURN, VAPOR, CHEMICAL VESSEL, TEST EQUIPMENT, EXPLOSION, LIGHTING, VALVE, ARM, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126005867 Hospitalized injury Burn/Scald(Heat) Chemical technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close