Inspection Detail
Inspection: 125999391 - Amerifloor Technical
Inspection Information - Office: San Diego District Office
Site Address:
Amerifloor Technical
8880 Rehco Rd
San Diego, CA 92121
Mailing Address:
7888 Silverton Ave #D, San Diego, CA 92126
Union Status: NonUnion
SIC:1752
NAICS: 238330/Flooring Contractors
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 12/06/1999
Emphasis:
Case Closed: 03/16/2010
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361640642 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 10 | 5 | 15 | |||
Current Violations | 8 | 3 | 11 | |||
Initial Penalty | $18,000 | $0 | $0 | $2,500 | $0 | $20,500 |
Current Penalty | $13,500 | $0 | $0 | $1,500 | $0 | $15,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 1509 A | 12/03/1999 | 01/05/2000 | $1,500 | $500 | $0 | 02/02/2000 | F - Formal Settlement | |
2. | 01002 | Other | 1510 C | 12/06/1999 | 01/08/2000 | $0 | $500 | $0 | 02/02/2000 | F - Formal Settlement | Citation has been deleted. |
3. | 01003 | Other | 1511 B | 12/06/1999 | 12/16/1999 | $0 | $500 | $0 | 02/02/2000 | F - Formal Settlement | Citation has been deleted. |
4. | 01004 | Other | 5144 F01 | 12/06/1999 | 01/08/2000 | $500 | $500 | $0 | 02/02/2000 | F - Formal Settlement | |
5. | 01005 | Other | 5144 G | 12/06/1999 | 12/16/1999 | $0 | $500 | $0 | 02/02/2000 | F - Formal Settlement | Citation has been deleted. |
6. | 02001 | Serious | 1534 A | 12/06/1999 | 12/16/1999 | $3,000 | $3,000 | $0 | 02/02/2000 | F - Formal Settlement | |
7. | 03001 | Serious | 1534 B | 12/06/1999 | 12/16/1999 | $1,500 | $3,000 | $0 | 02/02/2000 | F - Formal Settlement | |
8. | 04001 | Serious | 1935 C | 12/06/1999 | 12/16/1999 | $1,500 | $1,500 | $0 | 02/02/2000 | F - Formal Settlement | |
9. | 05001 | Other | 1513 E | 12/06/1999 | 12/16/1999 | $500 | $1,500 | $0 | 02/02/2000 | F - Formal Settlement | |
10. | 06001 | Serious | 1514 C | 12/06/1999 | 12/16/1999 | $1,500 | $1,500 | $0 | 02/02/2000 | F - Formal Settlement | |
11. | 07001 | Serious | 1522 A | 12/06/1999 | 12/16/1999 | $1,500 | $1,500 | $0 | 02/02/2000 | F - Formal Settlement | |
12. | 08001 | Other | 1528 A | 12/06/1999 | 12/16/1999 | $500 | $1,500 | $0 | 02/02/2000 | F - Formal Settlement | |
13. | 09001 | Serious | 1528 B | 12/06/1999 | 12/16/1999 | $1,500 | $1,500 | $0 | 02/02/2000 | F - Formal Settlement | |
14. | 10001 | Serious | 5144 A | 12/06/1999 | 12/16/1999 | $1,500 | $1,500 | $0 | 02/02/2000 | F - Formal Settlement | |
15. | 11001 | Serious | 1530 A02 | 12/06/1999 | 12/16/1999 | $0 | $1,500 | $0 | 02/02/2000 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
Three employees of a polymeric floor coating application contractor were seriously burned while using an electric floor buffer. The employees were using a methyl ethyl ketone solvent to strip an uncured floor when the vapors from the solvent ignited from a spark from the floor buffer. All three employees were working inside a small bathroom, approximately 1,000 cubic ft, when the fire occurred. Employee #1 was operating a floor buffer with brush attachment. The buffer was a Waxie Model 17, a 17-in. electric floor buffer with a 1-horse power, 120-volt electrical motor. The motor was an induction motor, but started with a centrifugal switch that is capable of sparking. Employee #1 was operating the floor buffer, while Employee #2 and Employee #3 poured the solvent onto the floor and then wiped behind the buffer with rags. Employee #1 suffered severe second-and-third-degree burns to 20 percent of his body. Employees #2 and #3 suffered similar injuries over a smaller percent of their body. The accident occurred at a customer's premises, during working hours. The fire caused significant damage to the bathroom, detaching a locked door and separating it from the door frame. The three employees were wearing half-mask respirators with an inappropriate cartridge, short-sleeve shirts, latex exam gloves and the only source of ventilation was from a ceiling fan rated at 6 to 9 air changes per hour. The employer had no safety plan for performing the floor stripping operation and did not bring portable ventilation to the site. When the employee's eyes became irritated, they donned swimming goggles purchased from a sporting goods store in the vicinity and continued to work until the fire occurred.
Keywords: BURN, MEK, VAPOR, VENTILATION, PPE, FIRE, SPARK
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 125999391 | Hospitalized injury | Burn/Scald(Heat) | Construction trades, n.e.c. | ||
2 | 125999391 | Hospitalized injury | Burn/Scald(Heat) | Construction trades, n.e.c. | ||
3 | 125999391 | Hospitalized injury | Burn/Scald(Heat) | Construction trades, n.e.c. |