Inspection: 125947697 - Western Freightway

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 125947697
Report ID: 0950631
Date Opened: 06/28/2005

Site Address:
Western Freightway
1550 E Kimberly Ave
Fullerton, CA 92831

Mailing Address:
6540 N Washington St, Denver, CO 80229

Union Status: NonUnion

SIC:4213

NAICS: 484121/ General Freight Trucking, Long-Distance, Truckload


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/10/2005

Emphasis:

Case Closed: 08/24/2005



Investigation Summary

Investigation Nr: 201146610
Event: 02/16/2005
Employee Is Pinned Between Forlift and Storage Rack

At approximately 1:42 p.m. on February 16, 2005, Employee #1, a trailer truck driver backed his vehicle into the receiving dock and walked to the warehouse. He stood next to a Yale forklift (Model GLP060TGEAE087-2004) when he was struck by another Yale forklift (Model GLP060TGEAE087-2004), driven by Employee #2. Employee #2 backed up his forklift, but was not aware that Employee #1 was behind him. Employee #1 was pinned between the forklift and a battery storage rack. Employee #1 was hospitalized with a fractured pelvis.

Keywords: FRACTURE, PINNED, EQUIPMENT OPERATOR, STRUCK AGAINST, CAUGHT BETWEEN, INDUSTRIAL TRUCK, PELVIS, STORAGE RACK, STRUCK BY, HIP

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125947697 Hospitalized injury Fracture Truck drivers, heavy
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.