Powered by GoogleTranslate

Inspection Detail

Inspection: 125917500 - Don Casters Gce Industries Inc

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 125917500
Report ID: 0950632
Date Opened: 07/13/2004

Site Address:
Don Casters Gce Industries Inc
1891 Nirvana Ave
Chula Vista, CA 91911

Mailing Address:
9353 Fairway View Dr., Rancho Cucamonga, CA 91730

Union Status: NonUnion

SIC:3498

NAICS: 332996/Fabricated Pipe and Pipe Fitting Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/13/2004

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/16/2010


Related Activity
Type Activity Nr Safety Health
Accident 362420325
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $500 $0 $500
Current Penalty $0 $0 $0 $280 $0 $280
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3556 B 11/19/2004 12/03/2004 $280 $500 $0 12/13/2004 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 201068004
Event: 05/19/2004
Employee Amputates Finger When Caught by Welding Fixture

On May 19, 2004, Employee #1, a welder, amputated his left index finger when it became caught between a pry bar he was using to lift a welding fixture and the table it was resting on. The employer manufactures parts for electrical power generation facilities. The welding fixture weighed between 1300 and 1400 pounds and was set on a work table. A small metal part was trapped under the edge of the fixture, holding it above level by 0.25 inch on one end. Employee #1 attempted to remove the metal part by using a flat piece of metal normally used for tapping parts into place as a pry bar. Unlike a manufactured pry bar, this bar was flat, not angled on one end to prevent the hand or fingers from being caught under the bar under excessive weight. When he freed the part from under the fixture, the entire weight of the fixture came down upon his finger, which was caught between the flat bar and the table. The flesh on his finger was removed when he pulled his hand away from the table. Employee #1 was hospitalized and the bone was later amputated by surgery to prevent infection.

Keywords: AMPUTATED, FINGER, WELDER, CAUGHT BETWEEN, PRY BAR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125917500 Hospitalized injury Amputation Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close