Inspection Detail
Inspection: 125907386 - Newport Exterminating
Inspection Information - Office: Santa Ana District Office
Site Address:
Newport Exterminating
43 S Hampton Ct
Newport Beach, CA 92660
Mailing Address:
16661 Millikan, Irvine, CA 92606
Union Status: NonUnion
SIC:7342
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/22/1997
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 11/04/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362224719 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $225 | $0 | $225 |
| Current Penalty | $0 | $0 | $0 | $225 | $0 | $225 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3328 F | 10/31/1997 | 11/05/1997 | $225 | $225 | $0 | - |
Investigation Summary
A fumigation department manager was placing a portable electric fan near a vent under a small outside porch at a residence. He was found the next morning by some coworkers. He was holding the fan support stand in one hand. In his other hand, he was holding the attachment plug on the fan's power supply cord and the cord connector on an extension cord set. He had been electrocuted.
Keywords: FAN, ELECTRICAL, CORD SET, E GI VII, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, CORD CONNECTOR, EQUIPMENT GROUNDING, ELECTRIC CORD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125907386 | Fatality | Electric Shock | Pest control occupations |