Inspection Detail
Inspection: 125904839 - Microdot
Inspection Information - Office: Santa Ana District Office
Site Address:
Microdot
190 W Crowther
Placentia, CA 92670
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3728
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/29/1996
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 09/13/2010
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362216343 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $600 | $0 | $600 |
| Current Penalty | $0 | $0 | $0 | $600 | $0 | $600 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 4202 C | 06/14/1996 | 06/29/1996 | $600 | $600 | $0 | - |
Investigation Summary
On February 24, 1996, Employee #1 was working on a Kenco crimping press, model 18-209, serial #68-007, that was equipped with a two-hand trip device and an anti-repeat feature. Due to a machine malfunction, the slide came down unexpectedly while Employee #1 was positioning a part. Her right hand became caught in the die at the point of operation, amputating part of her little finger. Her ring finger also sustained deforming injuries. Employee #1 was taken to the University of California at Irvine Medical Center for treatment.
Keywords: AMPUTATED, POWER PRESS, FINGER, CAUGHT BETWEEN, POINT OF OPERATION, PRESS OPERATOR, HAND, MECH MALFUNCTION, PRESS
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125904839 | Hospitalized injury | Amputation | Machine operators, not specified |
Translate