Inspection Detail
Inspection: 125904797 - Universal Alloy Corp
Inspection Information - Office: Santa Ana District Office
Site Address:
Universal Alloy Corp
2871 La Mesa Ave P O Box 6316
Anaheim, CA 92806
Mailing Address:
2871 La Mesa Ave P O Box 6316, Anaheim, CA 92806
Union Status: NonUnion
SIC:3339
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/10/1996
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 05/21/1996
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362219636 |
Investigation Summary
Employees #1 and #2, both press operators, were operating an aluminum extrusion press when a hydraulic hose developed a leak. Hydraulic fluid sprayed out in a small stream under pressure and then partially vaporized. The heat and flame from a nearby oven ignited the fluid, resulting in a flash fire. Employees #1 and #2 sustained second- and third-degree burns.
Keywords: BURN, LEAK, FLAMMABLE LIQUID, FLAMMABLE VAPORS, OVEN, FIRE, HYDRAULIC FLUID, HYDRAULIC LINE, PRESS OPERATOR, PRESS
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 125904797 | Hospitalized injury | Burn/Scald(Heat) | Misc. metal & plastic processing machine operators | ||
2 | 125904797 | Hospitalized injury | Burn/Scald(Heat) | Misc. metal & plastic processing machine operators |