Inspection Detail
Inspection: 125900498 - Dynamic Air Engineering Inc
Inspection Information - Office: Santa Ana District Office
Site Address:
Dynamic Air Engineering Inc
620 E Dyer Rd
Santa Ana, CA 92707
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3728
NAICS: 0
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/02/1995
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/15/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 76358258 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $4,000 | $0 | $0 | $300 | $0 | $4,300 |
| Current Penalty | $4,000 | $0 | $0 | $300 | $0 | $4,300 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 23400023 | 05/19/1995 | 05/24/1995 | $100 | $100 | $0 | - | ||
| 2. | 01002 | Other | 342 A | 05/19/1995 | 05/24/1995 | $200 | $200 | $0 | - | ||
| 3. | 02001 | Serious | 4206 A | 05/19/1995 | 05/24/1995 | $4,000 | $4,000 | $0 | - |
Investigation Summary
Employee #1, a machine operator, was operating a 10-ton mechanical punch press, feeding the material by hand. The guards had been raised and, when he placed his hand in the point of operation, the press stroked and amputated his left index finger at the first knuckle.
Keywords: AMPUTATED, FINGER, GUARD, WORK RULES, POINT OF OPERATION, PRESS OPERATOR, PUNCH PRESS, UNGUARDED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125900498 | Hospitalized injury | Amputation | Punching and stamping press machine operators |