Powered by GoogleTranslate

Inspection Detail

Inspection: 125885152 - Kiewit Industrial Co

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 125885152
Report ID: 0950633
Date Opened: 11/05/2003

Site Address:
Kiewit Industrial Co
19000 Perimeter Road
Victorville, CA 92394

Mailing Address:
19000 Perimeter Road E, Victorville, CA 92394

Union Status: Union

SIC:1791

NAICS: 238120/Structural Steel and Precast Concrete Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/13/2004

Emphasis:

Case Closed: 05/08/2018


Related Activity
Type Activity Nr Safety Health
Accident 101152601
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 3 5
Current Violations 1 1 2
Initial Penalty $19,350 $0 $0 $5,685 $0 $25,035
Current Penalty $7,200 $0 $0 $5,000 $0 $12,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 04/13/2004 05/17/2004 $5,000 $5,000 $0 05/18/2004 F - Formal Settlement  
2. 01002 Other 1509 A 04/13/2004 05/17/2004 $0 $135 $0 05/18/2004 F - Formal Settlement Citation has been deleted.
3. 01003 Other 3328 B 04/13/2004 05/17/2004 $0 $550 $0 05/18/2004 F - Formal Settlement Citation has been deleted.
4. 02001 Other 1670 B19 04/13/2004 04/26/2004 $0 $4,950 $0 05/18/2004 F - Formal Settlement Citation has been deleted.
5. 03001 Serious 1670 B11 B 04/13/2004 04/26/2004 $7,200 $14,400 $0 05/18/2004 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201158458
Event: 10/16/2002
Employee Falls From Top Edge Enclosure

At approximately 10:00 a.m. on October 16, 2002, Employee #1, an iron worker, was installing the wall and roof steel panel on a 21-foot-high generator, which was located at a power plant under construction in Victorville, California. As he was walking along the top edge of the enclosure, his retractable cable line jerked him, causing him to loose his balance and fall over the top edge of a 21-foot-high enclosure. He injured his lower back, hip, leg, and head. He had surgery on his lower back. He was hospitalized for three days.

Keywords: HEAD, ROOF, BACK, FALL, HIP, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125885152 Hospitalized injury Other Structural metal workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.