Inspection Detail
Inspection: 125883595 - R W Lyall & Company Inc
Inspection Information - Office: San Bernardino District Office
Site Address:
R W Lyall & Company Inc
2665 Research Drive
Corona, CA 92882
Mailing Address:
Post Office Box 2259, Corona, CA 92878
Union Status: NonUnion
SIC:3823
NAICS: 334513/ Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/29/2005
Emphasis:
Case Closed: 07/24/2008
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102443678 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 1 | 3 | ||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $18,000 | $0 | $10,000 | $2,000 | $0 | $30,000 |
Current Penalty | $3,150 | $0 | $0 | $2,000 | $0 | $5,150 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3203 A07 B | 11/29/2005 | 12/29/2005 | $2,000 | $2,000 | $0 | 01/03/2006 | J - ALJ Decision | |
2. | 02001 | Other | 342 A | 11/29/2005 | 12/12/2005 | $0 | $10,000 | $0 | 01/03/2006 | J - ALJ Decision | Citation has been deleted. |
3. | 03001 | Serious | 4184 B | 11/29/2005 | 12/02/2005 | $3,150 | $18,000 | $0 | 01/03/2006 | J - ALJ Decision |
Investigation Summary
At about 8:00 a.m. on July 01, 2005, Employee #1 was a recently hired regular employee working for a company that manufactured natural gas distribution fittings. She was located in the Plastic Department of the manufacturing facility, operating a LYCOFIT Model Number 153 non-destructive test machine. She was placing a 2 in. IPS (iron pipe size) plastic gas tapping tee in the top four-pronged area of the machine with her left hand. This area is like a top die, i.e., a part holder. As she was putting the tapping tee in place, she inadvertently pressed the test machine's control lever with her right hand. Her left hand got caught between the downward-moving part holder and the inverted half-circle bottom test die. Employee #1 sustained a partial amputation of the middle and ring fingers of her left hand. She was initially taken to the Industrial Medical Clinic, in Corona, CA, for treatment. She was transferred to Southern California Orthopedic Specialists, in Riverside, CA., where surgery was performed. She was not hospitalized.
Keywords: DIE, AMPUTATED, FINGER, CAUGHT BY, TEST EQUIPMENT, CAUGHT BETWEEN, INEXPERIENCE, PIPE, TESTING LAB, GAS FITTING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 125883595 | Non Hospitalized injury | Amputation | Production helpers |