Powered by GoogleTranslate

Inspection Detail

Inspection: 125881243 - Guy Evans Inc

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 125881243
Report ID: 0950633
Date Opened: 02/27/2006

Site Address:
Guy Evans Inc
82-585 Showcase Parkway
Indio, CA 92202

Mailing Address:
P.O. Box 10630, Indio, CA 92202

Union Status: NonUnion

SIC:2431

NAICS: 321911/Wood Window and Door Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/05/2006

Emphasis:

Case Closed: 03/22/2010


Related Activity
Type Activity Nr Safety Health
Accident 102448289
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 3 2 5
Initial Penalty $39,370 $0 $0 $375 $0 $39,745
Current Penalty $15,180 $0 $0 $375 $0 $15,555
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 B 04/05/2006 04/28/2006 $375 $375 $0 -  
2. 02001 Other 3203 A 04/05/2006 04/19/2006 $0 $5,060 $0 05/15/2006 F - Formal Settlement  
3. 03001 Serious 3328 B 04/05/2006 04/19/2006 $5,060 $5,060 $0 05/15/2006 F - Formal Settlement  
4. 04001 Serious 4186 A 04/05/2006 04/19/2006 $5,060 $6,750 $0 05/15/2006 F - Formal Settlement  
5. 05001 Serious 4300 A 04/05/2006 04/19/2006 $5,060 $22,500 $0 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202442489
Event: 02/10/2006
Employee Amputates Finger on Unguarded Saw Blade

At approximately 1:00 p.m. on February 10, 2006, Employee #1 was ripping a work piece that was 12-ft by 5-inch by 0.75-inch using a table saw, a DeWALT, DW746, Serial Number 16213, 1.75-HP, 3,000 rpm, with a 10-inch blade. He was taking 0.75-inch off the 5-inch side. The saw blade was not guarded by the hood guard. It was a common practice to remove the hood guard assembly supplied with the saw from the manufacturer while performing this type of cut on this material to avoid damaging the wood with the pawl's fingers. The hood guard assembly includes the spreader and the anti-kickback pawls along with the hood guard. At the time of the accident, the blade projected at least 0.5-inch above the material being cut. The rip fence was not parallel to the line of the saw blade. In the middle of the cut, while Employee #1's left hand was placed on the work piece against the table, and his right hand was holding the tail end of the work piece, the work piece lifted up. Employee #1 pushed the work piece back down with his left hand into the unguarded blade, and his left index finger was amputated. Employee #1 was transported to John F Kennedy Memorial Hospital, where he was admitted for treatment.

Keywords: AMPUTATED, FINGER, WORK RULES, MACHINE OPERATOR, STRUCK AGAINST, BLADE, UNGUARDED, TABLE SAW

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125881243 Hospitalized injury Amputation Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.