Powered by GoogleTranslate

Inspection Detail

Inspection: 125874602 - Parker Personnel, Inc.

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 125874602
Report ID: 0950635
Date Opened: 08/28/2013

Site Address:
Parker Personnel, Inc.
6006 Schull St
Bell Gardens, CA 90201

Mailing Address:
5027 Gage Ave, Bell Gardens, CA 90201

Union Status: NonUnion

SIC:7363

NAICS: 561320/Temporary Help Services


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/13/2014

Emphasis:

Case Closed: 09/15/2014


Related Activity
Type Activity Nr Safety Health
Accident 101037679
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $0 $0 $0 $5,000 $0 $5,000
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 01/14/2014 02/07/2014 $0 $5,000 $0 01/27/2014 D - Govt Dismissed Citation has been deleted.

Investigation Summary

Investigation Nr: 202532131
Event: 08/13/2013
Employee's Finger Is Amputated in Bottle Inflating Machine

At approximately 4:00 p.m. on August 13, 2013, Employee #1 was operating a semi-automatic blowing molding machine (Model Number ZQ22-III-IV, Serial Number 20111113). He was tasked with placing two preheated plastic tubs onto the half open-cylinder mold (10 in. in front of the point of operation). Employee #1 then applied two hands onto the two-hand control device to bring the tubs into the point of operation: closing the open-cylinder mold with the other half closed-cylinder mold, where air was blown into the plastic tubs to form the bottles. While the tubs were travelling into the point of operation, he saw one of the plastic tubs not in the correct position. He released his hand from the two-hand control device to retrieve the plastic tub. He placed his hand into the point of operation by reaching through and under the point of operation guard. His left middle finger was caught in between the molds, amputating the fingertip. Employee #1 was taken to a hand specialist clinic, where he was treated and was then released after three hours.

Keywords: AMPUTATED, FINGER, GUARD, CAUGHT BY, POINT OF OPERATION, MACHINE--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125874602 Non Hospitalized injury Amputation Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close