Inspection Detail
Inspection: 125839753 - Moyle Excavation, Inc.
Inspection Information - Office: American Canyon District Office
Site Address:
Moyle Excavation, Inc.
Highway 26 & Hogan Road
Valley Springs, CA 95252
Mailing Address:
P.O. Box 498, Jamestown, CA 95327
Union Status: NonUnion
SIC:1794
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/01/1999
Emphasis:
Case Closed: 09/10/1999
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362079352 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $0 | $0 | $0 | $450 | $0 | $450 |
| Current Penalty | $0 | $0 | $0 | $450 | $0 | $450 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 03/09/1999 | 02/18/1999 | $150 | $150 | $0 | - | ||
| 2. | 01002 | Other | 14301 A01 | 03/09/1999 | 03/01/1999 | $150 | $150 | $0 | - | ||
| 3. | 01003 | Other | 3328 G | 03/09/1999 | 02/18/1999 | $150 | $150 | $0 | - |
Investigation Summary
On September 10, 1998, an "O-ring" seal failed in the two-bolt adapter of the hydraulic control valves. The control valves were located inside the cab of a 621 paddle wheel Caterpillar scraper. The fluid sprayed into the cab, seriously burning Employee #1 when it was ignited by an unknown source. Employee #1 was hospitalized.
Keywords: BURN, SCRAPER, BOLT, VALVE, SEAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125839753 | Hospitalized injury | Burn(Chemical) | Paving, surfacing and tamping equipment operators |
Translate