Inspection Detail
Inspection: 125838219 - American Chevrolet
Inspection Information - Office: American Canyon District Office
Site Address:
American Chevrolet
4742 Mchenry Ave
Modesto, CA 95356
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5511
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/15/1999
Emphasis:
Case Closed: 10/17/2000
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361670573 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $0 | $0 | $0 | $1,000 | $0 | $1,000 |
| Current Penalty | $0 | $0 | $0 | $1,000 | $0 | $1,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 5194 H02 E | 10/13/1999 | 10/24/1999 | $500 | $500 | $0 | - | ||
| 2. | 01002 | Other | 5417 D | 10/13/1999 | 10/24/1999 | $500 | $500 | $0 | - |
Investigation Summary
On April 14, 1999, Employee #1 was injured while operating a battery powered buffer cleaning a floor. Employee #1 suffered burn injuries to the hands, chest and part of the face. Employee #1 was hospitalized.
Keywords: BURN, HEAT, FLAMMABLE LIQUID, EXPLOSION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125838219 | Hospitalized injury | Burn/Scald(Heat) | Janitors and cleaners |