Inspection Detail
Inspection: 125833665 - Convanta Energy Dba Burney Mountain Power
Inspection Information - Office: Sacramento District Office
Site Address:
Convanta Energy Dba Burney Mountain Power
37800 Energy Dr
Burney, CA 96013
Mailing Address:
Po Box 2375, Burney, CA 96013
Union Status: NonUnion
SIC:4911
NAICS: 221119/Other Electric Power Generation
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/17/2006
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/24/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101179729 |
Investigation Summary
On June 30, 2006, Employee #1, a utility operator, was closing a metal access door to the dryer system. The door was an inspection port, which was used to clear debris from a feeder system. The door was difficult to close, thus Employee #1 moved his right hand to the edge of the door as he closed it. Employee #1's little finger was caught between the door and the edge of the air duct frame. The tip of Employee #1's little finger was amputated by the heavy metal door.
Keywords: AMPUTATED, DUCT, FINGER, CAUGHT BETWEEN, DOOR, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125833665 | Non Hospitalized injury | Amputation | Miscellaneous material moving equipment operators |
Translate