Inspection: 125780585 - Gudgel/Yancy Roofing, Inc.

Inspection Information - Office: Sacramento District Office

 

Inspection Nr: 125780585
Report ID: 0950621
Date Opened: 03/08/2001

Site Address:
Gudgel/Yancy Roofing, Inc.
Jefferson & West Capital
Sacramento, CA 95841

Mailing Address:
5321 84th St, Sacramento, CA 95828

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/17/2001

Emphasis: S:Construction (Cship)

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 361709868
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $14,400 $0 $0 $0 $0 $14,400
Current Penalty $14,400 $0 $0 $0 $0 $14,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 1632 B 05/04/2001 05/09/2001 $14,400 $14,400 $0 05/23/2001 J - ALJ Decision  

Investigation Summary

Investigation Nr: 170626295
Event: 03/07/2001
Employee injured when he falls through a roof opening

At approximately 11:48 a.m. on March 7, 2001, Employee #1 was putting down a hot tar roof and was stapling down a base material. The roof had several openings covered by wooden pallets. The wheels of the staple gun ran into one of the pallets and Employee #1 moved the pallet partially back. As he rolled the staple gun pass the opening, he fell 22 to 26 ft to a concrete floor. He was hospitalized for multiple broken bones and a head trauma.

Keywords: FRACTURE, HEAD, ROOF, UNGUARDED FL OPENING, STRUCK AGAINST, ROOFER, FALL, ROOF OPENING, CONCRETE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125780585 Hospitalized injury Fracture Roofers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.