Powered by GoogleTranslate

Inspection Detail

Inspection: 125756767 - Oliveri Cabinets Inc

Inspection Information - Office: Modesto District Office

 

Inspection Nr: 125756767
Report ID: 0950624
Date Opened: 05/10/2004

Site Address:
Oliveri Cabinets Inc
23725 S. Chrisman
Tracy, CA 95304

Mailing Address:
23725 S. Chrisnan, Tracy, CA 95304

Union Status: NonUnion

SIC:2511

NAICS: 337122/Nonupholstered Wood Household Furniture Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/25/2004

Emphasis:

Case Closed: 06/16/2004


Related Activity
Type Activity Nr Safety Health
Accident 362352544

Investigation Summary

Investigation Nr: 201104742
Event: 03/23/2004
Employee's hand punctured by wood piece

On March 23, 2004, an employee was operating shaper. He was standing beside machine when wood kicked back and went through his right hand. The only equipment involved was a Steff 38 power feed and a SEC TS70 shaper, both made in Italy. The employee sustained puncture wound to his right hand. He was hospitalized and treated for his wounds.

Keywords: WOOD SHAPER, HAND, PUNCTURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125756767 Hospitalized injury Puncture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.