Powered by GoogleTranslate

Inspection Detail

Inspection: 125740621 - C & C Containers

Inspection Information - Office: Modesto District Office

 

Inspection Nr: 125740621
Report ID: 0950624
Date Opened: 12/11/2001

Site Address:
C & C Containers
401 Nestle Way
Lathrop, CA 95330

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3085

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/31/2001

Emphasis:

Case Closed: 01/31/2002


Related Activity
Type Activity Nr Safety Health
Accident 361712623
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $1,125 $0 $1,125
Current Penalty $0 $0 $0 $1,125 $0 $1,125
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 01/04/2002 02/06/2002 $300 $300 $0 -  
2. 01002 Other 3314 A 01/04/2002 02/06/2002 $450 $450 $0 -  
3. 01003 Other 3314 G 01/04/2002 02/06/2002 $225 $225 $0 -  
4. 01004 Other 3314 H 01/04/2002 02/06/2002 $150 $150 $0 -  

Investigation Summary

Investigation Nr: 201102233
Event: 11/02/2001
Employee's Thigh Lacerated by Machine

At approximately 11:30 p.m. on November 2, 2001, Employee #1 was working on the Zecchitte Palletizer Number 9, making an adjustment to the photo eye of the bottle placer mechanism. The Zecchitte Palletizer Number 9 has a "cage" around it, with a door, to prevent anyone from entering the machine while it is in operation. If the cage door is opened for any reason, the Zecchitte Palletizer Number 9 shuts down. The operator's panel has a master shut off switch. Once the master shut off switch is activated, the operator needs to manually reset three buttons to start up the Zecchitte Palletizer Number 9. On the night of the incident, the maintenance employee had the operator open the cage door and activate the master shut off switch. During the photo eye adjustment period, the maintenance employee shut the cage door and told the operator to activate the machine. When the machine turned on, the lever cut into Employee #1's left inner thigh. The employee was hospitalized.

Keywords: MAINTENANCE, MACHINE OPERATOR, LOCKOUT, CAUGHT BETWEEN, LACERATION, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125740621 Hospitalized injury Cut/Laceration Mechanical controls and valve repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.