Powered by GoogleTranslate

Inspection Detail

Inspection: 125655720 - White Magic Carpet & Cleaning

Inspection Information - Office: American Canyon District Office

 

Inspection Nr: 125655720
Report ID: 0950622
Date Opened: 03/12/1998

Site Address:
White Magic Carpet & Cleaning
1950 Olivera Road, Suite C
Concord, CA 94520

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7217

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/27/1998

Emphasis:

Case Closed: 10/01/1998


Related Activity
Type Activity Nr Safety Health
Accident 362083404
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $900 $0 $0 $150 $0 $1,050
Current Penalty $900 $0 $0 $150 $0 $1,050
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 05/27/1998 06/01/1998 $150 $150 $0 -  
2. 02001 Serious 3203 A04 B 05/27/1998 06/01/1998 $750 $750 $0 -  
3. 03001 Serious 3203 A07 D 05/27/1998 06/01/1998 $75 $75 $0 -  
4. 04001 Serious 5141 A 05/27/1998 06/01/1998 $75 $75 $0 -  

Investigation Summary

Investigation Nr: 170865612
Event: 02/22/1998
Employee suffers from carbon monoxide exposure

On Friday, February 20, 1998, Employee #1, who worked for a carpet cleaning and restoration company, finished the day's work at a privately-owned condominium that had been damaged by water. The unit was unoccupied and had no electricity, so the employer had rented a gasoline-powered generator to power fans and dehumidifiers indoors. Employee #1 left the generator running when he departed that night. Unbeknownst to his employer, he returned to the job site on Saturday and Sunday to sleep because he did not have a home. He was exposed to the carbon monoxide from the generator as he slept. Employee #1 hospitalized for a week, but he is expected to make a full recovery.

Keywords: VAPOR, VENTILATION, WORK RULES, INHALATION, EXHAUST FUMES, SLEEPING QUARTERS, CHEMICAL VAPOR, OVEREXPOSURE, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125655720 Hospitalized injury Asphyxia Janitors and cleaners
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close