Inspection Detail
Inspection: 125640953 - Thermionics Laboratory,Inc
Inspection Information - Office: Oakland District Office
Site Address:
Thermionics Laboratory,Inc
22815 Sutro Street
Hayward, CA 94540
Mailing Address:
P.O. Box 3711, Hayward, CA 94540
Union Status: NonUnion
SIC:3826
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/28/1996
Emphasis:
Case Closed: 03/12/1996
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361621170 |
Investigation Summary
On December 14, 1995, Employee #1, a machinist with over five years of employment, was operating a Bridgeport vertical milling machine, series 1, turret model BR2J. She had touched the cutter to the port and measured the cut mark with a caliper to ensure correct position. Her fingertip was amputated by the cutter because she was not watching her hand as she lowered it from the spindle. She was treated at a local hospital and released the following day. Employee #1 could not explain why she was not watching her left hand when it was close to the cutter. Vertical millers are not normally equipped with point of operation guards.
Keywords: AMPUTATED, FINGER, MACHINIST, WORK RULES, MILLING MACHINE, BLADE, INATTENTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125640953 | Non Hospitalized injury | Amputation | Occupation not reported |