Powered by GoogleTranslate

Inspection Detail

Inspection: 125583948 - 3 Com Corporation

Inspection Information - Office: Fremont District Office

 

Inspection Nr: 125583948
Report ID: 0950612
Date Opened: 01/22/1997

Site Address:
3 Com Corporation
5400 Bayfront Plaza
Santa Clara, CA 95052

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3672

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/25/1997

Emphasis:

Case Closed: 09/30/1997


Related Activity
Type Activity Nr Safety Health
Accident 361392533
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $0 $0 $0 $1,200 $0 $1,200
Current Penalty $0 $0 $0 $1,200 $0 $1,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 25100058 B 03/04/1997 03/21/1997 $150 $150 $0 -  
2. 01002 Other 3702 B 03/04/1997 04/06/1997 $150 $150 $0 -  
3. 01003 Other 5185 G 03/04/1997 03/07/1997 $150 $150 $0 -  
4. 01004 Other 5185 E 03/04/1997 03/21/1997 $150 $150 $0 -  
5. 01005 Other 5185 J 03/04/1997 03/07/1997 $600 $600 $0 -  

Investigation Summary

Investigation Nr: 170886519
Event: 01/06/1997
Employee injured when pinned between vehicle and wall

At approximately 3:00 p.m. on January 6, 1997, a coworker arrived at the service area to store and charge an electric vehicle. While parking it, the coworker saw Employee #1 standing near the building door. The coworker exited the vehicle on the driver's side, placed the electrical cord and outlet box on the floor of the driver's side, and closed the door. Employee #1 walked to other side of vehicle, opened the passenger side door, and retrieved the battery charger from near the compactor. While she was lifting the charger into the vehicle, the coworker and Employee #1 had a brief conversation. Employee #1 then walked in front of the vehicle while the coworker tried to put the charger on the floor of the passenger side. The charger either slipped or fell out of the coworker's hands. It landed on the accelerator pedal, moving the vehicle forward approximately 1 to 2 ft. Employee #1's right leg was pinned against the wall; her left leg was struck by the front end of the vehicle, and she was knocked to the ground. The coworker pulled the vehicle off her and notified 911. The accident was the result of the driver's failure to properly position the operating controls on the electrical vehicle. The coworker had received inadequate training regarding the safe operation of the electrical vehicle and battery charger, and no operations manual was provided for training employees. The employer was cited for violations of T8CCR 5185(g), for allowing smoking in a designated battery charging area; of T8CCR 5185(e), for not protecting the battery charger from damage by mobile equipment; of T8CCR 2510.58(b), for missing grounding pin from battery charger; of T8CCR 3702(b), for an inoperable horn on the electrical vehicle and missing directional selector name plate; and T8CCR 5185(j), for mobile equipment controls not being properly positioned.

Keywords: ACCELERATOR PEDAL, VEHICLE IN GEAR, PINNED, WORK RULES, STRUCK BY, UNMANNED, LOST CONTROL, UNTRAINED, MOTOR VEHICLE, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125583948 Hospitalized injury Fracture Engineering technicians, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close