Powered by GoogleTranslate

Inspection Detail

Inspection: 125575076 - Tci Of California

Inspection Information - Office: Fremont District Office

 

Inspection Nr: 125575076
Report ID: 0950612
Date Opened: 03/16/1999

Site Address:
Tci Of California
1762 Clear Lake Avenue
Milpitas, CA 95035

Mailing Address:
1900 S 10th Street, San Jose, CA 95103

Union Status: Union

SIC:4841

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/01/1999

Emphasis:

Case Closed: 11/16/2000


Related Activity
Type Activity Nr Safety Health
Accident 101794006
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $300 $0 $300
Current Penalty $0 $0 $0 $300 $0 $300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3664 A 07/26/1999 08/28/1999 $300 $300 $0 -  
2. 02001 Other 6151 E02 07/26/1999 08/28/1999 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 202311791
Event: 03/05/1999
Employee injured when he falls from telephone pole

Employee #1 was climbing a telephone pole to service cable television equipment in front of a house. As he reached his approximate height goal he began to circle the pole by inserting a gaff on one foot into the pole and then the gaff on the other foot would be brought closer and inserted into the pole. The gaffs must be inserted positively to hold the weight of the climber. Employee #1 feels he did not insert the first gaff sufficiently into the pole and it gave way as he transferred his weight. Employee #1 suffered torn ligaments in the left foot and contusions to the back and was hospitalized.

Keywords: CABLE TV WORK, FALL, CUTOUT--GAFF, FOOT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125575076 Hospitalized injury Strain/Sprain Telephone line installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close