Powered by GoogleTranslate

Inspection Detail

Inspection: 125517300 - Bay City Boiler & Engineering Co., Inc.

Inspection Information - Office: Foster City District Office

 

Inspection Nr: 125517300
Report ID: 0950613
Date Opened: 03/31/1999

Site Address:
Bay City Boiler & Engineering Co., Inc.
220 Park Road
Burlingame, CA 94010

Mailing Address:
915 Linden Avenue, So. San Francisco, CA 94080

Union Status: Union

SIC:7699

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/20/1999

Emphasis:

Case Closed: 08/12/2002


Related Activity
Type Activity Nr Safety Health
Accident 362301012
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $225 $0 $225
Current Penalty $0 $0 $0 $150 $0 $150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5157 C04 08/20/1999 09/22/1999 $0 $75 $0 W - Empr Withdrew  
2. 02001 Other 5157 D05 B 08/20/1999 08/25/1999 $150 $150 $0 09/30/1999 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 201121423
Event: 03/29/1999
Employee burned when acetylene gas ignites

On March 31, 1999, Employee #1 entered the fire chamber of a firebox boiler to make repairs. The chamber is small and considered a confined space. The space was free of hazardous and toxic contaminants at the time Employee #1 entered. Employee #1 entered the space with an oxy-acetylene torch. Employee #1 had to lie down to do the welding. As he was welding some molten slag fell on him and started to burn him. Employee #1 scraped the slag off of him and in doing so dropped the torch which then extinguished. The escaping oxy-acetylene gas quickly filled the chamber and ignited when Employee #1 tried to light the torch again. Employee #1 sustained second-degree burns to the face and side of his body.

Keywords: BURN, ACETYLENE TORCH, CONFINED SPACE, ACETYLENE, BOILER, FIRE, TORCH, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125517300 Hospitalized injury Burn/Scald(Heat) Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close