Powered by GoogleTranslate

Inspection Detail

Inspection: 125516476 - M Bumgarner, Inc.

Inspection Information - Office: Foster City District Office

 

Inspection Nr: 125516476
Report ID: 0950613
Date Opened: 10/17/1997

Site Address:
M Bumgarner, Inc.
University Ave. & Hwy 84
East Palo Alto, CA 94303

Mailing Address:
1175 Grennville Road, Livermore, CA 94550

Union Status: Union

SIC:1611

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/28/1998

Emphasis:

Case Closed: 09/20/1999


Related Activity
Type Activity Nr Safety Health
Accident 362302432
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $4,500 $0 $0 $250 $0 $4,750
Current Penalty $3,000 $0 $0 $250 $0 $3,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 01/30/1998 02/04/1998 $250 $250 $0 -  
2. 02001 Serious 2946 B03 01/30/1998 02/04/1998 $3,000 $4,500 $0 02/26/1998 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201120490
Event: 10/11/1997
electric shock & burn - contact with overhead line thru boom

An employee was supervising the placement of metal rails on the median of a highway. The supervisor instructed the crane operator to use the remote controls of the truck-mounted crane to move the truck while the operator was in the operator cab. To make sure the crane did not stray in to traffic lanes, the supervisor was directing the operator as he backed-up. The supervisor was holding the outrigger when the crane contacted a 115-kilovolt overhead power line. He sustained an electric shock and was severely burned on his left arm and right foot. He was hospitalized for his injuries.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, E C, ELECTRIC SHOCK, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125516476 Hospitalized injury Electric Shock Supervisors, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close