Powered by GoogleTranslate

Inspection Detail

Inspection: 125508770 - Napa Electric Shop Inc.

Inspection Information - Office: American Canyon District Office

 

Inspection Nr: 125508770
Report ID: 0950615
Date Opened: 01/05/1998

Site Address:
Napa Electric Shop Inc.
2240 Brown Street
Napa, CA 94558

Mailing Address:
, , 00000

Union Status: Union

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/10/1998

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/10/1998


Related Activity
Type Activity Nr Safety Health
Accident 362137408

Investigation Summary

Investigation Nr: 170764401
Event: 12/18/1997
Employee's fingertip amputated in pipe threading machine

Employee #1, a journeyman, was cleaning a stationary pipe and bolt threading machine, model #535, at a winery construction site. He was reaching into the machine to remove the threaded pipe nipple when his right index finger was pinched against the sharp parts and rail, amputating approximately 3/8 in. of the tip.

Keywords: AMPUTATED, THREADING MACHINE, FINGER, WORK RULES, CLEANING, STRUCK AGAINST, CONSTRUCTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125508770 Non Hospitalized injury Cut/Laceration Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.