Powered by GoogleTranslate

Inspection Detail

Inspection: 125507582 - Dental Masters Dba Durametrics Inc.

Inspection Information - Office: American Canyon District Office

 

Inspection Nr: 125507582
Report ID: 0950615
Date Opened: 04/02/1997

Site Address:
Dental Masters Dba Durametrics Inc.
816 Piner Road
Santa Rosa, CA 95401

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:8072

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/21/1997

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/17/1997


Related Activity
Type Activity Nr Safety Health
Accident 362136475
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 4 4
Initial Penalty $0 $0 $0 $650 $0 $650
Current Penalty $0 $0 $0 $250 $0 $250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23200002 A03 05/21/1997 05/27/1997 $0 $400 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Other 23400024 05/21/1997 05/21/1997 $50 $50 $0 -  
3. 01003 Other 25000008 A01 05/21/1997 05/21/1997 $50 $50 $0 -  
4. 01004 Other 25000009 A 05/21/1997 05/27/1997 $50 $50 $0 -  
5. 01005 Other 23400023 05/21/1997 05/27/1997 $100 $100 $0 -  

Investigation Summary

Investigation Nr: 170727788
Event: 03/30/1997
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

A maintenance worker was adjusting an electrical grid in a high-frequency Electromatic II casting machine in a dental laboratory. He was kneeling on the floor with his hand inside the machine. The employee was not complying with written procedures and had bypassed an interlock on the machine. He apparently contacted energized parts and received an electric shock. He also sustained burns to both hands.

Keywords: BURN, E GI IV, ELECTRICAL, ELECTRICAL WORK, INTERLOCK, LOCKOUT, ELEC CIRC PART--MISC, ELECTRIC SHOCK, ELEC EQUIPMENT--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125507582 Non Hospitalized injury Electric Shock Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.