Inspection Detail
Inspection: 125505511 - Dorseys Auto Repair & Body Shop
Inspection Information - Office: American Canyon District Office
Site Address:
Dorseys Auto Repair & Body Shop
359 North School Street
Ukiah, CA 95482
Mailing Address:
1211 North State Street, Ukiah, CA 95482
Union Status: NonUnion
SIC:7538
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/09/1997
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/22/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362136921 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 6 | 6 | ||||
| Current Violations | 6 | 6 | ||||
| Initial Penalty | $0 | $0 | $0 | $410 | $0 | $410 |
| Current Penalty | $0 | $0 | $0 | $410 | $0 | $410 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 4845 B | 05/09/1997 | 05/14/1997 | $110 | $110 | $0 | - | ||
| 2. | 01002 | Other | 3577 E | 05/09/1997 | 05/14/1997 | $75 | $75 | $0 | - | ||
| 3. | 01003 | Other | 25000008 A02 | 05/09/1997 | 05/14/1997 | $75 | $75 | $0 | - | ||
| 4. | 01004 | Other | 25000008 A 5 | 05/09/1997 | 06/19/1997 | $0 | $0 | $0 | - | ||
| 5. | 01005 | Other | 6151 C01 | 05/09/1997 | 05/14/1997 | $75 | $75 | $0 | - | ||
| 6. | 01006 | Other | 23400022 A | 05/09/1997 | 05/14/1997 | $75 | $75 | $0 | - |
Investigation Summary
Employee #1 was at his place of employment, working on a personal project to repair a leak in a tank. He was using a welding machine and 150 psi of air pressure when the water tank exploded. Employee #1 sustained a fractured tibia and lacerations to his right thigh. Causal factors of this accident include (1) the use of inappropriate procedures; and (s) misuse of a water tank for an air pressure tank for the employee's personal use and in opposition to the employer's policy.
Keywords: AIR PRESSURE, FRACTURE, REPAIR, WORK RULES, WELDING, EXPLOSION, HIGH PRESSURE, TANK, WATER TANK, LEG
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125505511 | Hospitalized injury | Fracture | Automobile mechanics |