Powered by GoogleTranslate

Inspection Detail

Inspection: 125490391 - Yum'S Mechanical

Inspection Information - Office: San Francisco District Office

 

Inspection Nr: 125490391
Report ID: 0950611
Date Opened: 07/27/1998

Site Address:
Yum'S Mechanical
1649 Jerrold Avenue
San Francisco, CA 94124

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3444

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/13/1999

Emphasis:

Case Closed: 01/13/1999


Related Activity
Type Activity Nr Safety Health
Accident 362189581
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 7 9
Current Violations 2 7 9
Initial Penalty $3,875 $0 $0 $375 $0 $4,250
Current Penalty $3,875 $0 $0 $375 $0 $4,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 01/13/1999 03/03/1999 $150 $150 $0 -  
2. 01002 Other 5202 D02 01/13/1999 02/15/1999 $75 $75 $0 -  
3. 01003 Other 5153 A 01/13/1999 02/15/1999 $0 $0 $0 -  
4. 01004 Other 5445 C 01/13/1999 02/15/1999 $0 $0 $0 -  
5. 01005 Other 5446 A 01/13/1999 02/15/1999 $0 $0 $0 -  
6. 01006 Other 5450 A 01/13/1999 02/15/1999 $0 $0 $0 -  
7. 01007 Other 5450 K 01/13/1999 02/15/1999 $150 $150 $0 -  
8. 02001 Serious 5449 F 01/13/1999 02/08/1999 $375 $375 $0 -  
9. 03001 Serious 5449 B 01/13/1999 02/08/1999 $3,500 $3,500 $0 -  

Investigation Summary

Investigation Nr: 201180015
Event: 07/22/1998
Burn - Electric Arc Ignited Spray-applied Adhesive

An employee working for a heating and ventilation contractor sprayed a coating of a flammable adhesive containing methylene chloride to the inner surface of a sheet metal duct section. The employee then positioned a piece of precut fiberglass insulation against the glued surface and allowed it to set for approximately 5 minutes. He then spot welded retention pins through the fiberglass insulation and onto the sheet metal using pinspot-type welded insulation fasteners. The electric arc generated by the spot welder ignited the flammable vapors from the adhesive, which were trapped in the air spaces in the insulation. The ensuing flash fire burned the employee's face, neck, right ear, and inner right forearm. He was hospitalized for 5 days. (The spray application of the flammable adhesive and the spot welding were conducted in a general shop area, not a well ventilated work station.)

Keywords: BURN, ELECTRIC ARC, SPOT WELDING, E GI III, ELECTRICAL, FLAMMABLE LIQUID, GLUE, WELDER, WELDING, THERMAL INSULATION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125490391 Hospitalized injury Burn/Scald(Heat) Sheet metal workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.