Inspection Detail
Inspection: 1254868.015 - Rice Poseidon Midstream Llc.
Inspection Information - Office: Pittsburgh Area Office
Site Address:
Rice Poseidon Midstream Llc.
344 Mcgirts Road
Daisytown, PA 15427
Mailing Address:
2200 Rice Drive, Canonsburg, PA 15317
Union Status: NonUnion
SIC:
NAICS: 213112/Support Activities for Oil and Gas Operations
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/08/2017
Emphasis:
Case Closed: 02/12/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1252880 | Yes | |
| Inspection | 1254895 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $7,243 | $0 | $0 | $0 | $0 | $7,243 |
| Current Penalty | $7,243 | $0 | $0 | $0 | $0 | $7,243 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100252 A02 XV | 12/07/2017 | $7,243 | $7,243 | $0 | Z - Issued |
Investigation Summary
At 8:00 a.m. on August 15, 2017, two employees were working from a JLB lift, welding steel support beams. The Unit C207 compressor was shut down which caused a release of natural gas from an exhaust pipe that was located a few feet below the JLG lift basket. The gas ignited by the welding above and both employees suffered burn injuries to their necks and head. One employee was hospitalized.
Keywords: Burn, Head, Natural Gas, Neck
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1254868.015 | 40 | M | Hospitalized injury | Occupation Not Listed |