Inspection Detail
Inspection: 125312983 - Harrell Farms
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Harrell Farms
1924 Hwy 125
Hobgood, NC 27843
Mailing Address:
Pob 28, Oak City, NC 27857
Union Status: NonUnion
SIC:0132
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/28/1996
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/28/1996
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100350115 |
Investigation Summary
Some employees were harvesting cotton. When the combine they were using filled, the employees decided to take the combine back to the buildings to unload rather than bring the truck to the field. When the employees elevated the combine to dump the load, the combine contacted a 7200-volt overhead power line. Two employees were touching the combine when it contacted the power line. One of them was electrocuted; the other received an electric shock for which he was hospitalized.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, AGRICULTURE, ELECTROCUTED, FARM MACHINERY, HARVESTER, ELECTRIC SHOCK, E AG
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 125312983 | Hospitalized injury | Electric Shock | Farm workers | ||
2 | 125312983 | Fatality | Electric Shock | Farm workers |