Powered by GoogleTranslate

Inspection Detail

Inspection: 125292524 - P.P.G. Industries, Inc.

Inspection Information - Office: Nc Department Of Labor - Charlotte

 

Inspection Nr: 125292524
Report ID: 0453730
Date Opened: 06/28/1994

Site Address:
P.P.G. Industries, Inc.
940 Washburn Switch Road
Shelby, NC 28150

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3296

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/26/1994

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/09/1994


Related Activity
Type Activity Nr Safety Health
Accident 360493159
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $7,000 $0 $0 $0 $0 $7,000
Current Penalty $7,000 $0 $0 $0 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 95012901 09/09/1994 09/15/1994 $3,500 $3,500 $0 -  
2. 01002A Serious 19100133 A01 09/09/1994 09/15/1994 $3,500 $3,500 $0 -  
3. 01002B Serious 19100132 C 09/09/1994 09/15/1994 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170055008
Event: 06/27/1994
Employees burned by molten glass eruption

Employees #1 through #5 were involved in the replacement of a defective water can below a furnace containing molten glass. Employees #1 and #2 were tapping the water can immediately below the furnace floor and Employee #5 was observing them. Employees #3 and #4 were manning fire hoses. After the molten glass had partly drained from the furnace, molten glass erupted from beneath Employees #3 and #4. Employees #1 and #2 were hospitalized for 3rd-degree burns to their heads, necks, faces, arms, backs, and shoulders. Employees #3, #4, and #5 suffered first- and second-degree burns to their hands, arms, and faces.

Keywords: BURN, FURNACE, REPAIR, ACCIDENTAL DISCHARGE, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125292524 Hospitalized injury Burn/Scald(Heat) Specified mechanics and repairers
2 125292524 Hospitalized injury Burn/Scald(Heat) Specified mechanics and repairers
3 125292524 Non Hospitalized injury Burn/Scald(Heat) Specified mechanics and repairers
4 125292524 Non Hospitalized injury Burn/Scald(Heat) Specified mechanics and repairers
5 125292524 Non Hospitalized injury Burn/Scald(Heat) Specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.