Inspection Detail
Inspection: 125287466 - Ashland Construction Co.
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Ashland Construction Co.
Alexander Ave.
Henderson, NC 27536
Mailing Address:
1301 Millbrook Rd., Raleigh, NC 27604
Union Status: NonUnion
SIC:1541
NAICS: 0
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/31/1995
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 07/02/1999
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 77503217 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
| Current Penalty | $3,500 | $0 | $0 | $0 | $0 | $3,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260416 A01 | 03/17/1995 | 03/23/1995 | $3,500 | $3,500 | $0 | 05/31/1995 | F - Formal Settlement | |
| 2. | 01002 | Serious | 19260416 A03 | 03/17/1995 | 03/23/1995 | $0 | $3,500 | $0 | 05/31/1995 | F - Formal Settlement |
Investigation Summary
A roof was being constructed between two existing buildings. One of the employees on the site contacted unguarded live parts of a 600-volt, three-phase circuit while he was working. The employee received an electric shock and was hospitalized for his injury.
Keywords: ROOF, ELECTRICAL, ELECTROCUTED, E C, ELEC CIRC PART--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125287466 | Hospitalized injury | Electric Shock | Construction trades, n.e.c. |
Translate