Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1252860.015 - Excel Modular Scaffold & Leasing Company

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 1252860.015
Report ID: 0626700
Date Opened: 08/07/2017

Site Address:
Excel Modular Scaffold & Leasing Company
2555 Savannah Ave
Port Arthur, TX 77640

Mailing Address:
7001 Tx-225, Deer Park, TX 77536

Union Status: NonUnion

SIC:

NAICS: 324110/Petroleum Refineries


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/07/2017

Emphasis: N:Chemnep

Case Closed: 07/05/2019


Related Activity
Type Activity Nr Safety Health
Referral 1248769 Yes
Inspection 1252869 Yes
Inspection 1281421 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $12,934 $0 $0 $0 $0 $12,934
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100119 H03 IV 02/01/2018 03/21/2018 $0 $12,934 $0 02/26/2018 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 97907.015
Event: 08/03/2017
Employee receives burn from fire and explosion while removin

At approximately 3:00 p.m. on August 3, 2017, an employee had just finished abatement, removal of insulation on piping when a fire and explosion occurred. The employee received third degree burns on back and front knees from direct heat. The employee was hospitalized and treated for burns.

Keywords: Back, Burn, Explosion, Fire, Insulator, Knee, Pipe

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1252860.015 56 M Hospitalized injury Construction Laborer
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close