Powered by GoogleTranslate

Inspection Detail

Inspection: 125219832 - Empresas De Gas Co Inc

Inspection Information - Office: Pr-E-San Juan 0257260

 

Inspection Nr: 125219832
Report ID: 0257260
Date Opened: 10/10/1995

Site Address:
Empresas De Gas Co Inc
Repto Ind Corujo Hato Tejas
Bayamon, PR 00619

Mailing Address:
Po Box 1025 Sabana Seca Sta, Toa Baja, PR 00951

Union Status: NonUnion

SIC:4925

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/07/1996

Emphasis:

Case Closed: 08/28/1996


Related Activity
Type Activity Nr Safety Health
Accident 361521834
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $3,000 $0 $0 $0 $0 $3,000
Current Penalty $1,800 $0 $0 $0 $0 $1,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100146 C02 04/02/1996 04/12/1996 $900 $1,500 $0 I - Informal Settlement  
2. 01002 Serious 19100146 G01 04/02/1996 04/19/1996 $900 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170075899
Event: 10/10/1995
Employee dies of oxygen deficiency in confined space

Employee #1 was repairing the rod of a gauge inside a Bobtail tank truck. Fifteen percent oxygen was present. Toxic substances present were hydrogen sulfide, 6 percent, carbon monoxide, 9 percent, and residues of propane. Employee #1 entered the tank without the required entrance permit for confined spaces. He died of oxygen deficiency. Employee #1 had not been trained in the procedures, hazards, and permit requirements to enter confined spaces. The employer did not post signs warning about unauthorized entrance into this confined space by either employees or others.

Keywords: OXYGEN DEFICIENCY, TANK TRUCK, ASPHYXIATED, CONFINED SPACE, HYDROGEN SULFIDE, WORK RULES, PROPANE, UNTRAINED, CARBON MONOXIDE, WARNING SIGN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125219832 Fatality Asphyxia Bus, truck and stationary engine mechanics
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close