Inspection Detail
Inspection: 1249721.015 - Jgg Construction, Llc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
Jgg Construction, Llc.
2590 Kelley Lake Road
Decatur, GA 30032
Mailing Address:
5900 Hunt Club Run Apt C, Norcross, GA 30093
Union Status: NonUnion
SIC:
NAICS: 236210/Industrial Building Construction
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/24/2017
Emphasis: L:Fall
Case Closed: 04/05/2022
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1243406 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 2 | 6 | |||
| Current Violations | 4 | 2 | 6 | |||
| Initial Penalty | $14,412 | $0 | $0 | $622 | $0 | $15,034 |
| Current Penalty | $14,412 | $0 | $0 | $622 | $0 | $15,034 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19101200 E01 | 01/12/2018 | 02/20/2018 | $2,772 | $2,772 | $0 | Z - Issued | ||
| 2. | 01001B | Serious | 19101200 H01 | 01/12/2018 | 02/20/2018 | $0 | $0 | $0 | Z - Issued | ||
| 3. | 01002 | Serious | 19260501 B10 | 01/12/2018 | 02/08/2018 | $3,880 | $3,880 | $0 | Z - Issued | ||
| 4. | 01003 | Serious | 19260502 H01 V | 01/12/2018 | 02/08/2018 | $3,880 | $3,880 | $0 | Z - Issued | ||
| 5. | 01004 | Serious | 19260503 B01 | 01/12/2018 | 02/08/2018 | $3,880 | $3,880 | $0 | Z - Issued | ||
| 6. | 02001 | Other | 19030019 C01 | 07/18/2018 | 08/13/2018 | $311 | $311 | $0 | Z - Issued | ||
| 7. | 02002 | Other | 19030019 D01 | 07/18/2018 | 08/13/2018 | $311 | $311 | $0 | Z - Issued |
Investigation Summary
At 2:00 p.m. on July 20, 2017, Employee #1, employed by a construction company, was performing roofing work at a building worksite. He stepped on a roll of roofing material that was extended over the edge of the roof and fell, a fall height of approximately 15.4 feet. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for a fractured left arm and lacerations that required sutures to his head and right elbow.
Keywords: Arm, Construction, Elbow, Fall, Fall Protection, Fracture, Head, Laceration, Material Handling, Roof
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1249721.015 | 34 | M | Hospitalized injury | Roofers |
Translate