Inspection: 124847005 - Sova & Son Contracting

Inspection Information - Office: Miosha Construction Safety & Health Division

 

Inspection Nr: 124847005
Report ID: 0552651
Date Opened: 09/24/1996

Site Address:
Sova & Son Contracting
1855 Hicks Rd
Midland, MI 48642

Mailing Address:
634 N Homer Rdy, Midland, MI 48640

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/07/1996

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/10/1997


Related Activity
Type Activity Nr Safety Health
Accident 101400067
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $6,000 $0 $0 $0 $0 $6,000
Current Penalty $4,050 $0 $0 $0 $0 $4,050
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 40841023A1 11/25/1996 11/28/1996 $1,350 $2,000 $0 12/20/1996 F - Formal Settlement  
2. 01002 Serious 40841023A4 11/25/1996 11/28/1996 $1,350 $2,000 $0 12/20/1996 F - Formal Settlement  
3. 01003 Serious 40841023A7 11/25/1996 11/29/1996 $1,350 $2,000 $0 12/20/1996 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201400116
Event: 09/23/1996
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Some employees were laying 203-millimeter-diameter water main pipe. There were no overhead power lines when they began working. However, as they progressed in their work, they approached an overhead power line. The employees were using two different excavators, one of which was larger than the other. At the driveway of a house near the power line, they switched to the larger excavator. The operator swung under the power line so that another employee could hook the pipe to the excavator bucket. That employee hooked the PVC pipe with a wire rope choker and walked away. The choker came loose, and he returned to the pipe to fix it. As he was holding onto the chocker, the boom on the excavator contacted the power line. The employee received an electric shock and was transported to a hospital, where he was pronounced dead of electrocution.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E C, EXCAVATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 124847005 Fatality Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.