Inspection Detail
Inspection: 124668401 - P & E Electric Co., Inc.
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
P & E Electric Co., Inc.
Hwy. 11 S. (South Union)
Fair Play, SC 29643
Mailing Address:
P. O. Box 101013, Nashville, TN 37224
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/18/1995
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 09/19/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362628356 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $975 | $0 | $0 | $0 | $0 | $975 |
| Current Penalty | $975 | $0 | $0 | $0 | $0 | $975 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260028 A | 09/01/1995 | 09/07/1995 | $975 | $975 | $0 | - |
Investigation Summary
A mechanic arrived at a site to repair a vehicle just as a power line crew was lifting a utility pole out of the ground. The crew foreman asked the mechanic to guide the bottom of the pole. The top of the pole contacted an overhead power line; and the mechanic, who was not wearing rubber insulating gloves, received an electric shock and burns. He was hospitalized for his injuries.
Keywords: BURN, ELEC PROTECT EQUIP, OVERHEAD POWER LINE, ELECTRICAL, E PTD, ELEC UTILITY WORK, ELECTRIC SHOCK, UNTRAINED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 124668401 | Hospitalized injury | Electric Shock | Bus, truck and stationary engine mechanics |
Translate