Inspection Detail
Inspection: 124667635 - Tietex, Inc.
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
Tietex, Inc.
3010 Black Stock Rd.
Spartanburg, SC 29301
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2297
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/07/1994
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 09/19/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360499453 |
Investigation Summary
Employee #1 was operating a strikeout machine that squeezes dyed cloth. Because the cloth was not feeding between the rollers correctly, Employee #1 stuck scissors behind the guard opening. The scissors and his hand were pulled into the rollers' nip point, crushing his fingers. The machine has 5 1/2 in. diameter rollers that measure 23 1/2 in. long and run at 21 rpm/9.2 yards per minute. A foot pedal activated an angle iron guard that covered the rollers' nip point. An emergency button was added to the machine after the accident because the emergency stop wire across the front of machine was an inadequate guard.
Keywords: MAINTENANCE, FINGER, GUARD, WORK RULES, CAUGHT BY, LOCKOUT, ROLLER--MACH/PART, CRUSHED, NIP POINT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 124667635 | Hospitalized injury | Amputation | Miscellaneous textile machine operators |
Translate