Inspection Detail
Inspection: 124635582 - Dyce Chemical
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
Dyce Chemical
390 Exchange Place
Ogden, UT 84402
Mailing Address:
P.O. Box 1708, Salt Lake City, UT 84402
Union Status: NonUnion
SIC:5169
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 09/26/1994
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 09/14/1995
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361533128 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 1 | 5 | |||
Current Violations | 4 | 1 | 5 | |||
Initial Penalty | $3,500 | $42,000 | $0 | $0 | $0 | $45,500 |
Current Penalty | $3,500 | $42,000 | $0 | $0 | $0 | $45,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Willful | 10200140201 | 10/28/1994 | 11/01/1994 | $42,000 | $42,000 | $0 | - | ||
2. | 01001B | Willful | 19100132 C | 10/28/1994 | 11/01/1994 | $0 | $0 | $0 | - | ||
3. | 02001A | Serious | 10200130101 | 10/28/1994 | 11/01/1994 | $875 | $875 | $0 | - | ||
4. | 02001B | Serious | 10200130201 | 10/28/1994 | 11/01/1994 | $0 | $0 | $0 | - | ||
5. | 02002 | Serious | 19100119 E01 | 10/28/1994 | 11/30/1994 | $875 | $875 | $0 | - | ||
6. | 02003A | Serious | 19100120 Q01 | 10/28/1994 | 11/30/1994 | $875 | $875 | $0 | - | ||
7. | 02003B | Serious | 19100120 Q06 III | 10/28/1994 | 11/30/1994 | $0 | $0 | $0 | - | ||
8. | 02004A | Serious | 19100134 B10 | 10/28/1994 | 11/30/1994 | $875 | $875 | $0 | - | ||
9. | 02004B | Serious | 19100134 E02 | 10/28/1994 | 11/30/1994 | $0 | $0 | $0 | - | ||
10. | 02004C | Serious | 19100134 E03 | 10/28/1994 | 11/30/1994 | $0 | $0 | $0 | - | ||
11. | 02004D | Serious | 19100134 E05 | 10/28/1994 | 11/30/1994 | $0 | $0 | $0 | - | ||
12. | 02004E | Serious | 19100134 F02 II | 10/28/1994 | 11/30/1994 | $0 | $0 | $0 | - |
Investigation Summary
At approximately 8:00 a.m. on September 12, 1995, Employee #1, a chemical worker for Dyce Chemical, Ogden, UT, entered the berm area of a 5,000 gallon capacity nitric acid tank that had been leaking 60 percent nitric acid in order to check a valve for leakage. He was dressed in a chemical splash suit and rubber boots and gloves, and was wearing an air purifying respirator equipped with acid cartridges. Because of the leakage, the berm area was filled to about a 20 inch depth with nitric acid and the valve was partially submerged in the acid. Employee #1 noticed a hot sensation on his legs and immediately climbed out of the berm. An unsuccessful attempt was made to remove the employee's chemical suit and boots (the lower edge of the chemical suit had been taped to the boot). A hose with running water was fed down through the top of the chemical splash suit while the boots and suit were cut off Employee #1. Emergency personnel were telephoned and they transported Employee #1 to the burn center at the University of Utah Medical Center.
Keywords: LEAK, EMERGENCY RESPONSE, WORK RULES, CHEMICAL BURN, NITRIC ACID, LEG
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 124635582 | Hospitalized injury | Burn(Chemical) | Mechanical controls and valve repairers |