Inspection Detail
Inspection: 124618976 - R & D Plumbing & Heating
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
R & D Plumbing & Heating
9800 South 3850 West
South Jordan, UT 84065
Mailing Address:
P.O. Box 9322, Ogden, UT 84409
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/16/1993
Planning Guide: Safety-Construction
Emphasis: N:Trench
Case Closed: 09/16/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361531304 |
Investigation Summary
At 8:20 a.m. on September 1, 1993, at the South Jordan Middle School construction site, Employee #1 was working in a trench when a backhoe (Case model 580) rolled into the trench and crushed him, killing him.
Keywords: CONSTRUCTION, TRENCH, CRUSHED, STRUCK BY, BACKHOE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 124618976 | Fatality | Concussion | Plumbers, pipefitters and steamfitters |
Translate