Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1246002.015 - University Of Maryland, College Park

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 1246002.015
Report ID: 0352420
Date Opened: 07/11/2017

Site Address:
University Of Maryland, College Park
Department Of Chemistry And Biochemistry 0107 Chemistry Building, 8051 Regents Drive, Room 2112
College Park, MD 20742

Mailing Address:
Department Of Environmental Safety, Sustainability, And Risk Seneca Building, Suite 0103, 4716 Pontiac Ave, College Park, MD 20742

Union Status: NonUnion

SIC:

NAICS: 611310/ Colleges, Universities, and Professional Schools


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: StateGovt

Safety/Health: Health

Close Conference: 07/20/2017

Emphasis:

Case Closed: 03/26/2018


Related Activity
Type Activity Nr Safety Health
Accident 1241127
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 A 08/23/2017 08/31/2017 $0 $0 $0 I - Informal Settlement  
2. 01002 Serious 19100133 A01 08/23/2017 08/31/2017 $0 $0 $0 I - Informal Settlement  
3. 01003 Serious 19100138 A 08/23/2017 08/31/2017 $0 $0 $0 I - Informal Settlement  
4. 01004 Serious 19101450 F01 08/23/2017 09/26/2017 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 97208.015
Event: 07/06/2017
Employee is sprayed with corrosive chemicals and suffers che

At 1:45 p.m. on July 6, 2017, an employee was working with a coworker and performing a laboratory cleanout operation. Both workers misidentified the contents of a centrifuge tube containing Piranha Solution and the employee poured the contents of the container into a bottle of concentrated nitric acid. The chemicals reacted, causing an exothermic reaction that turned the bubbling contents brown in color as nitrogen dioxide built up in the reaction vessel. The employee partially threaded the cap on the container hoping that it would vent. He was still holding the container when the top exploded, spraying nitric acid and reaction products into his face and eyes. The employee suffered chemical burns to those areas. The employee was hospitalized.

Keywords: Accidental Discharge, Chemical, Chemical Burn, Chemical Reaction, Explosion, Struck By

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1246002.015 28 M Hospitalized injury Chemical technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.