Inspection Detail
Inspection: 1244996.015 - Pall Corporation
Inspection Information - Office: Jacksonville Area Office
Site Address:
Pall Corporation
1750 Filter Dr.
Deland, FL 32724
Mailing Address:
1750 Filter Dr., Deland, FL 32724
Union Status: NonUnion
SIC:
NAICS: 333999/All Other Miscellaneous General Purpose Machinery Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/06/2017
Emphasis: N:Amputate
Case Closed: 09/27/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1234568 | Yes |
Investigation Summary
At approximately 10:30 a.m. on June 27, 2017, an employee was reaching under a machine guard to pull out a jammed filter bag. The employee reached into the point of operation of a cutting and heat sealing machine to pull a jammed/stuck filter bag. As the bag was removed, a light sensor reactivated the carriage, catching the employee's forearm in the point of operation. The employee received several puncture wounds to the forearm and was hospitalized.
Keywords: Caught In, Forearm, Jammed, Lockout/Tagout, Machine Guarding, Point Of Operation, Puncture
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1244996.015 | 57 | M | Hospitalized injury | Miscellaneous machine operators, n.e.c. |