Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1244638.015 - Reo Processing West Virginia, Inc.

Inspection Information - Office: Charleston Area Office

 

Inspection Nr: 1244638.015
Report ID: 0316400
Date Opened: 07/05/2017

Site Address:
Reo Processing West Virginia, Inc.
221 Airport Industrial Park Road
Parkersburg, WV 26104

Mailing Address:
221 Airport Industrial Park Road, Parkersburg, WV 26104

Union Status: NonUnion

SIC:

NAICS: 493110/General Warehousing and Storage


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/21/2017

Emphasis:

Case Closed: 09/29/2017


Related Activity
Type Activity Nr Safety Health
Referral 1225027 Yes
Complaint 1251944 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 96859.015
Event: 05/24/2017
Employee suffers chemical burn and suffers foot amputation l

On May 24, 2017, an employee was sorting out and packaging chlorine base pool chemical. The employee was checked by his supervisor and went to the Marietta Memorial Hospital due to a blister on the bottom of his foot. The employee saw a specialist the next day who diagnosed the injury as a chemical burn. The employee's foot required amputation at a later date.

Keywords: Amputated, Amputation, Chemical Burn, Chlorine, Foot

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1244638.015 24 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close