Inspection Detail
Inspection: 124074352 - Kake Fisheries
Inspection Information - Office: Alaska Department Of Labor Osh Enforcement
Site Address:
Kake Fisheries
Cold Storage Building
Kake, AK 99830
Mailing Address:
Box 400, Kake, AK 99830
Union Status: NonUnion
SIC:2092
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 07/21/1994
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 02/08/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360179808 |
Investigation Summary
At approximately 5:30 a.m. on July 12, 1994, Employee #1 was operating a propane-powered forklift inside a closed door cold storage warehouse. Employee #1 was overexposed to carbon monoxide from the defective forklift. Another employee came into the warehouse, found Employee #1 disoriented, and moved him outside the warehouse to fresh air. Mouth to mouth resuscitation was administered to Employee #1 and he was transported to a hospital.
Keywords: ENCLOSED SPACE, IND TRK OPERATOR, VENTILATION, WORK RULES, TOXIC ATMOSPHERE, INHALATION, INDUSTRIAL TRUCK, EXHAUST FUMES, OVEREXPOSURE, CARBON MONOXIDE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 124074352 | Hospitalized injury | Asphyxia | Occupation not reported |
Translate