Powered by GoogleTranslate

Inspection Detail

Inspection: 124054594 - Robison & Hauer Masonry Corporation

Inspection Information - Office: Indiana Department Of Labor

 

Inspection Nr: 124054594
Report ID: 0551800
Date Opened: 12/16/1992

Site Address:
Robison & Hauer Masonry Corporation
(Scottsburg Plastics Tad Plant #2) South Gardner
Scottsburg, IN 47170

Mailing Address:
Attn Billy Guy Robison R R 6, Scottsburg, IN 47170

Union Status: NonUnion

SIC:1741

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/20/1993

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/27/1994


Related Activity
Type Activity Nr Safety Health
Accident 361307648
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 6
Current Violations 4 2 6
Initial Penalty $4,650 $0 $0 $0 $0 $4,650
Current Penalty $3,487 $0 $0 $0 $0 $3,487
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 02/02/1993 02/05/1993 $1,125 $1,500 $0 02/18/1993 R - Review Commission  
2. 01002 Serious 19260416 A01 02/02/1993 02/05/1993 $1,125 $1,500 $0 02/18/1993 R - Review Commission  
3. 01003 Serious 19260451 D03 02/02/1993 02/05/1993 $450 $600 $0 02/18/1993 R - Review Commission  
4. 01004 Serious 19260451 D10 02/02/1993 02/05/1993 $787 $1,050 $0 02/18/1993 R - Review Commission  
5. 02001 Other 19260451 A03 02/02/1993 02/05/1993 $0 $0 $0 02/18/1993 R - Review Commission  
6. 02002 Other 19260451 D04 02/02/1993 02/05/1993 $0 $0 $0 02/18/1993 R - Review Commission  

Investigation Summary

Investigation Nr: 170105795
Event: 12/15/1992
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU METAL ROD

TWO CONSTRUCTION LABORERS ("HOD CARRIERS") WERE WORKING FROM A 15-FOOT-HIGH TUBULAR, WELDED FRAME SCAFFOLD. THEY WERE DROPPING A 20-FOOT-LONG, 0.5-INCH-DIAMETER REINFORCING ROD INTO A 19.33-FOOT-HIGH CONCRETE BLOCK WALL. A 7200-VOLT OVERHEAD POWER LINE WAS LOCATED ABOUT 11.5 FEET ABOVE THE SCAFFOLD (26.5 FEET ABOVE THE GROUND). THE REINFORCING ROD CONTACTED THE POWER LINE, AND THE EMPLOYEES RECEIVED ELECTRIC SHOCKS. ONE OF THEM WAS ELECTROCUTED; THE OTHER WAS HOSPITALIZED OVERNIGHT FOR OBSERVATION AND FOR TREATMENT OF INJURIES HE SUSTAINED TO HIS LEFT HAND AND KNEE.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, REBAR, ELECTROCUTED, ELECTRIC SHOCK, E GI IC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 124054594 Fatality Electric Shock Construction laborers
2 124054594 Hospitalized injury Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close