Powered by GoogleTranslate

Inspection Detail

Inspection: 123942450 - Polar Construction

Inspection Information - Office: Sacramento District Office

 

Inspection Nr: 123942450
Report ID: 0950621
Date Opened: 05/26/1992

Site Address:
Polar Construction
24850 Ben Taylor Rd.
Colfax, CA 95722

Mailing Address:
4340 Stockton Blvd., Sacramento, CA 95820

Union Status: NonUnion

SIC:1542

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/05/1992

Emphasis:

Case Closed: 04/12/1994


Related Activity
Type Activity Nr Safety Health
Accident 361334329
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $1,400 $0 $0 $0 $0 $1,400
Current Penalty $1,400 $0 $0 $0 $0 $1,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 06/05/1992 05/26/1992 $0 $0 $0 -  
2. 01003 Other 1710 B 06/05/1992 05/26/1992 $0 $0 $0 -  
3. 01004 Other 1710 C04 06/05/1992 05/12/1992 $0 $0 $0 -  
4. 01005 Other 3203 A07 D 06/05/1992 05/26/1992 $0 $0 $0 -  
5. 02001 Serious 1716 D01 06/05/1992 05/26/1992 $1,400 $1,400 $0 -  

Investigation Summary

Investigation Nr: 170717839
Event: 05/15/1992
Employee injured when knocked from lift by falling beam

On Thursday, May 21, 1992, at the Colfax Elementary School construction site in Colfax, CA, a general contractor requested help from a carpentry crew to erect a 50 ft steel beam and columns; neither the general contractor nor the carpenter were trained in steel erection. The steel beam was raised into position using two forklifts. Guys were set at one end, but the column footing bolts were not secured, and only one guy was attached at the other end. When the two guys were attached at the east end, the forklift sling was released by Employee #1, of Polar Construction, who was working from a scissor lift. When the single guy was attached at the west end, the fork released the tension on the chain sling (the other guy was not attached because the turnbuckle had broken two weeks earlier when the beam had been originally set by an erection crew). The chain sling unhooked when the tension was released. Because the beam was not guyed at one corner and the column footings were not tightened, the beam leaned over, unwrapping the chain sling. The weight and force of the beam pulled the turnbuckle apart on the northeast corner. The beam then fell over onto the scissor lift, knocking Employee #1 to the concrete floor. He landed on his back and head, sustaining severe head injuries. First aid was administered and he was then transported by helicopter to UC Medical Center in Sacramento for treatment of his head injuries.

Keywords: HEAD, STEEL BEAM, CONSTRUCTION, INDUSTRIAL TRUCK, STEEL ERECTION, GUY, FALL, STRUCK BY, FALLING OBJECT, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123942450 Hospitalized injury Concussion Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close