Powered by GoogleTranslate

Inspection Detail

Inspection: 123928145 - Le Prino Foods

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 123928145
Report ID: 0950625
Date Opened: 09/21/1994

Site Address:
Le Prino Foods
Fox At E Street N/E Corner
Lemoore, CA 93245

Mailing Address:
490 "F" Street, Lemoore, CA 93245

Union Status: Union

SIC:2022

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/22/1994

Emphasis:

Case Closed: 06/24/1996


Related Activity
Type Activity Nr Safety Health
Accident 361388382
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,000 $0 $0 $0 $0 $3,000
Current Penalty $600 $0 $0 $0 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3203 A 09/30/1994 10/31/1994 $600 $3,000 $0 10/21/1994 J - ALJ Decision  

Investigation Summary

Investigation Nr: 170717318
Event: 04/05/1994
Employee's fingertip amputated by air actuated valves

Employee #1, an untrained relief worker in the cheese department, was instructed to clean air activated valves with both 4 in. and 2 in. valve bodies at cheese vats #1 through #8. The working foreman states that he showed Employee #1 how similar valves had been cleaned. Having each completed eight 4 in. valves, Employee #1 and the foreman began working on CIP system 2 in. valves. They split up with Employee #1 working vats #2, #4, #6, and #8, and the foreman working vats #1, #3, #5, and #7. After he completed vats #2 and #4, Employee #1 attempted to install a valve plug assembly into the actuator, valve #253, on vat #6. When the air line was connected to the actuator, Employee #1's little finger became trapped between the valve plug and valve body. The application of air caused the air actuator to function immediately, causing the valve plug to retract into the actuator body. The movement of the valve plug assembly trapped his little finger, causing the partial amputation of the fingertip. He was moved for medical treatment to Hanford Medical Center, Hanford, CA, where he was treated and released.

Keywords: AIR PRESSURE, AMPUTATED, FINGER, CLEANING, CAUGHT BETWEEN, VALVE, AIR LINE, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123928145 Non Hospitalized injury Amputation Food batchmakers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.