Inspection Detail
Inspection: 123926552 - Pacific Bell
Inspection Information - Office: Fresno District Office
Site Address:
Pacific Bell
20574 Jackson Ave.
Lemoore, CA 93245
Mailing Address:
, , 00000
Union Status: Union
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/04/1993
Emphasis:
Case Closed: 05/19/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361373509 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 6 | 6 | ||||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $33,125 | $0 | $0 | $0 | $0 | $33,125 |
| Current Penalty | $6,250 | $0 | $0 | $3,270 | $0 | $9,520 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 1515 A03 | 08/04/1993 | 03/05/1993 | $6,250 | $6,250 | $0 | J - ALJ Decision | Citation has been deleted. | |
| 2. | 02001 | Serious | 8602 H | 08/04/1993 | 02/05/1993 | $6,250 | $6,250 | $0 | J - ALJ Decision | ||
| 3. | 03001 | Serious | 8603 A | 08/04/1993 | 09/21/1993 | $5,000 | $5,000 | $0 | J - ALJ Decision | Citation has been deleted. | |
| 4. | 04001 | Serious | 1509 A | 08/04/1993 | 09/21/1993 | $6,250 | $6,250 | $0 | J - ALJ Decision | Citation has been deleted. | |
| 5. | 05001 | Other | 3648 O | 08/04/1993 | 02/05/1993 | $930 | $3,125 | $0 | J - ALJ Decision | ||
| 6. | 06001 | Other | 3648 E | 08/04/1993 | 02/05/1993 | $2,340 | $6,250 | $0 | J - ALJ Decision |
Investigation Summary
A TELEPHONE LINE WORKER WAS WORKING FROM THE BUCKET OF AN AERIAL LIFT. HE WAS NOT WEARING HEAD PROTECTION OR PERSONAL FALL PROTECTION EQUIPMENT. EVEN THOUGH THE WORK HE WAS PERFORMING BROUGHT HIM NEAR A 12-KILOVOLT OVERHEAD POWER LINE, THE JOB PLAN FOR HIS WORK DID CONTAIN ANY CAUTIONS REGARDING THE POWER LINE. (ADDITIONALLY, THE EMPLOYEE'S WORK TECHNIQUE WAS INCORRECT. HE WAS CUTTING THE TELEPHONE CABLE, SHORTING OUT THE TELEPHONE SERVICE, RATHER THAN OPENING THE SPLICE AND TRIMMING THE CONDUCTORS.) THE EMPLOYEE'S WORKING POSITION IN THE AERIAL LIFT VIOLATED THE 24-INCH MINIMUM APPROACH DISTANCE FROM THE OVERHEAD POWER LINE. AS HE WAS CUTTING THE CABLE WITH CABLE CUTTERS, HE CONTACTED THE POWER LINE AND WAS ELECTROCUTED.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, TELECOM WORK, E TC, ELECTROCUTED, AERIAL LIFT, COMMUNICATION WORKER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123926552 | Fatality | Electric Shock | Telephone line installers and repairers |