Inspection Detail
Inspection: 123900797 - Dt Performance Specialties Inc
Inspection Information - Office: Santa Ana District Office
Site Address:
Dt Performance Specialties Inc
1371 N Miller St
Anaheim, CA 92806
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3498
NAICS: 332996/Fabricated Pipe and Pipe Fitting Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/16/2006
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 05/16/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362360869 |
Investigation Summary
On December 2, 2005, a saw operator was operating a Doringer specialty pipe cut-off saw, Model D350, Serial Number 1954. His employer was an after-market high-performance exhaust pipe manufacturer. The D350 cut-off saw was manually operated and ran at two different speeds (58 and 108 RPM). The employee was cutting a 10-inch section of three-inch diameter exhaust pipe. The pipe got caught on the saw blade, which pulled the pipe and the employee's finger into the rotating blade. The employee suffered an amputation of his left index finger and was hospitalized.
Keywords: AMPUTATED, FINGER, ROTATING KNIFE, MACHINE OPERATOR, CAUGHT BY, SAW, METAL SAW, PIPE, BLADE, METAL PIPE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 123900797 | Hospitalized injury | Amputation | Sawing machine operators |